1 / 9
SOLAREDGE S440 Power Optimizer (REF: 4005370) (5 PCS)
- Current bid
- Status
€
Total bid amount
See total breakdown
Total bid amount
See total breakdown
€
Max bid amount
See total breakdown
Max bid amount
See total breakdown
Lot specifications
- Quantity
- 1
- Margin
- No
- Brand
- SOLAREDGE
- Model
- S440
- Terms of delivery
- Loaded on truck
Description
Model: SolarEdge S440
INPUT (DC)
Rated DC input power: 440W
Absolute maximum input voltage (module Voc at minimum temperature): 60 Vdc
MPPT operating range: 8 – 60 Vdc
Maximum short-circuit current (Isc) of the connected PV module: 14.5 A
Maximum efficiency: 99.5 %
Weighted efficiency: 98.6 %
Overvoltage category: II
OUTPUT DURING OPERATION
Maximum Output Current: 15 Adc
Maximum output voltage: 60 Vdc
EXIT DURING STAND-BY
Safety output voltage for power optimizer: 1 ± 0.1 Vdc
STANDARDS
COMPLIANCE Electromagnetic compatibility: FCC Part 15 Class B, IEC 61000-6-2, IEC 61000-6-3, CISPR 11, EN 55011
Safety: IEC 62109-1 (Safety Class II), UL1741
Materials: UL94 V-0, UV
resistant RoHS compliant: Yes
Fire safety: VDE-AR-E 2100-712:2018-12
INSTALLATION
SPECIFICATIONS Maximum permissible voltage of the system: 1000 Vdc
Dimensions (W × H × D): 129 × 155 × 30 mm
Weight: 720 g
Input Connector: MC4
Input cable length: 0.1 m
Output Connector: MC4
Output cable length: (+) 2.3 m / (−) 0.10 m
Operating temperature range: −40°C ~ +85°C
Protection class: IP68
Relative humidity: 0 – 100 %
Single piece loading dimensions: 400 x 400 x 300 mm
INPUT (DC)
Rated DC input power: 440W
Absolute maximum input voltage (module Voc at minimum temperature): 60 Vdc
MPPT operating range: 8 – 60 Vdc
Maximum short-circuit current (Isc) of the connected PV module: 14.5 A
Maximum efficiency: 99.5 %
Weighted efficiency: 98.6 %
Overvoltage category: II
OUTPUT DURING OPERATION
Maximum Output Current: 15 Adc
Maximum output voltage: 60 Vdc
EXIT DURING STAND-BY
Safety output voltage for power optimizer: 1 ± 0.1 Vdc
STANDARDS
COMPLIANCE Electromagnetic compatibility: FCC Part 15 Class B, IEC 61000-6-2, IEC 61000-6-3, CISPR 11, EN 55011
Safety: IEC 62109-1 (Safety Class II), UL1741
Materials: UL94 V-0, UV
resistant RoHS compliant: Yes
Fire safety: VDE-AR-E 2100-712:2018-12
INSTALLATION
SPECIFICATIONS Maximum permissible voltage of the system: 1000 Vdc
Dimensions (W × H × D): 129 × 155 × 30 mm
Weight: 720 g
Input Connector: MC4
Input cable length: 0.1 m
Output Connector: MC4
Output cable length: (+) 2.3 m / (−) 0.10 m
Operating temperature range: −40°C ~ +85°C
Protection class: IP68
Relative humidity: 0 – 100 %
Single piece loading dimensions: 400 x 400 x 300 mm
Additional details
Items sold in unverified status.