1 / 8
SOLAREDGE P404 Power Optimizer (REF: 4002690)
- Current bid
- Status
€
Total bid amount
See total breakdown
Total bid amount
See total breakdown
€
Max bid amount
See total breakdown
Max bid amount
See total breakdown
Lot specifications
- Quantity
- 1
- Margin
- No
- Brand
- SOLAREDGE
- Model
- P404
- Terms of delivery
- Loaded on truck
Description
Model: SolarEdge P404
INPUT (DC)
Rated DC input power: 405W
Absolute maximum input voltage (Voc at minimum temperature): 80 Vdc
MPPT operating voltage range: 12.5 – 80 Vdc
Maximum short-circuit current (Isc): 11 A
Maximum efficiency: 99.5 %
Weighted efficiency: 98.8 %
Overvoltage category: II
OUTPUT OPERATION (optimizer connected to operational SolarEdge inverter)
Maximum Output Current: 15 Adc
Maximum output voltage: 80 Vdc
STANDBY OUTPUT (optimizer disconnected from SolarEdge inverter or inverter off)
Safety output voltage for optimizer: 1 ± 0.1 Vdc
STANDARDS
COMPLIANCE Electromagnetic compatibility: FCC Part 15 Class B, IEC 61000-6-2, IEC 61000-6-3
Safety: IEC 62109-1 (Safety Class II), UL1741
RoHS compliant: Yes
Fire safety: VDE-AR-E 2100-712:2013-05
INSTALLATION
SPECIFICATIONS Maximum allowable system voltage: 1000 Vdc
Dimensions (W × D × H): 129 × 153 × 42.5 mm
Weight (including cables): 775 g
Input connector: MC4 (single or double, depending on configuration)
Input cable length: 0.16 / 0.52 m
Output Connector: MC4
Output cable length: 1.2 m
Operating temperature range: −40°C ~ +85°C
Degree of protection: IP68
Relative humidity: 0 – 100 %
Single piece loading dimensions: 400 x 400 x 300 mm
INPUT (DC)
Rated DC input power: 405W
Absolute maximum input voltage (Voc at minimum temperature): 80 Vdc
MPPT operating voltage range: 12.5 – 80 Vdc
Maximum short-circuit current (Isc): 11 A
Maximum efficiency: 99.5 %
Weighted efficiency: 98.8 %
Overvoltage category: II
OUTPUT OPERATION (optimizer connected to operational SolarEdge inverter)
Maximum Output Current: 15 Adc
Maximum output voltage: 80 Vdc
STANDBY OUTPUT (optimizer disconnected from SolarEdge inverter or inverter off)
Safety output voltage for optimizer: 1 ± 0.1 Vdc
STANDARDS
COMPLIANCE Electromagnetic compatibility: FCC Part 15 Class B, IEC 61000-6-2, IEC 61000-6-3
Safety: IEC 62109-1 (Safety Class II), UL1741
RoHS compliant: Yes
Fire safety: VDE-AR-E 2100-712:2013-05
INSTALLATION
SPECIFICATIONS Maximum allowable system voltage: 1000 Vdc
Dimensions (W × D × H): 129 × 153 × 42.5 mm
Weight (including cables): 775 g
Input connector: MC4 (single or double, depending on configuration)
Input cable length: 0.16 / 0.52 m
Output Connector: MC4
Output cable length: 1.2 m
Operating temperature range: −40°C ~ +85°C
Degree of protection: IP68
Relative humidity: 0 – 100 %
Single piece loading dimensions: 400 x 400 x 300 mm
Additional details
Items sold in unverified status.